Skip to main content

The Dual Therapy Auto 250 and Auto 250F are dynamic replacement systems with a safe working load of 250kg.

The surfaces have been manufactured to be used on profiling beds within the hospital, home or long term care facility and are indicated for patients who have been identified as very high risk of developing a pressure ulcer.

  • There are 20, figure of 8 cells offering support and comfort to patients in a variety of positions.
  • The lower section of each cell remains static or in continuous low pressure mode.
  • The cells within the DTAuto250 are 20cm in height and have a lower chamber filled with air.
  • The DTAuto250F has a cell height of 15cm and a lower chamber pouch containing a 5cm layer of foam.
Alternating Low Pressure and Continuous Low Pressure Therapies

Alternating Low Pressure and Continuous Low Pressure Therapies

  • Offers a solution to meet each patients unique support needs in just one system.
  • Simple and intuitive control unit interface.
  • Choice of 4 cycle times; 10, 15, 20 and 25 minutes.
Continuously improving our solutions by using data collected and customer feedback

Automatic Cell Pressure

  • Provides the ideal pressure for the individual patient, based on their weight, posture and bed position.
  • Ensures optimal pressure redistribution to provide immersion and envelopment, calibrated every 10 minutes to account for any changes in patient position.
  • Reduces set-up time, releasing time to care.
Auto Firm

Auto Firm

  • Fully inflates the cells to provide a firmer surface for patient repositioning.
  • Defaults to the previous therapy after 20 minutes.
  • Can be cancelled at any time by pressing the AutoFirm button.
Journey Planner

Transport Mode

  • Easily set-up by detaching the CPR tubing from the control unit and attaching the transport cap supplied.
  • The surface remains inflated for up to 8 hours ensuring pressure redistribution is provided when transportation is required.
  • Can also be activated during a power outage to ensure the patient continues to remain safe.

CPR

  • Easy to locate and access, the rapid CPR deflation tag is conveniently located at the head end of the surface.
  • When the patient is being cared for at home, the pull tag design is easy to activate for those carers with poor dexterity (in cases where emergency services may instruct for the CPR to be activated in preparation for them arriving at the property).
  • The cells immediately deflate.
  • leaving the patient on a firm surface so staff can carry out the emergency resuscitation procedure.

Specification

  • Risk level: Very High
  • Safe Working Load: up to 250kg
  • Surface Dimensions: L 2003mm x W 900mm x H 200mm
  • Surface Weight: 10.1kg
  • Number of cells: 20
  • Cover Material: PU coated polyester
  • High frequency welded seams
  • Control Unit Dimensions: L 370mm x W 140mm x H 250mm
  • Control Unit Weight: 6.2kg
  • Warranty: 2 years (surface & cover)
  • 8 hour transport mode
  • Static head section
  • Seat position inflate – for additional sacral support
  • Cable management
View BrochureDownload Technical Specification

For more information

Get in touch